1.
Artículo en Inglés | MEDLINE | ID: mdl-38306026

RESUMEN

BACKGROUND: Differentiation of high-flow from low-flow vascular malformations (VMs) is crucial for therapeutic management of this orphan disease. OBJECTIVE: A convolutional neural network (CNN) was evaluated for differentiation of peripheral vascular malformations (VMs) on T2-weighted short tau inversion recovery (STIR) MRI. METHODS: 527 MRIs (386 low-flow and 141 high-flow VMs) were randomly divided into training, validation and test set for this single-center study. 1) Results of the CNN's diagnostic performance were compared with that of two expert and four junior radiologists. 2) The influence of CNN's prediction on the radiologists' performance and diagnostic certainty was evaluated. 3) Junior radiologists' performance after self-training was compared with that of the CNN. RESULTS: Compared with the expert radiologists the CNN achieved similar accuracy (92% vs. 97%, p = 0.11), sensitivity (80% vs. 93%, p = 0.16) and specificity (97% vs. 100%, p = 0.50). In comparison to the junior radiologists, the CNN had a higher specificity and accuracy (97% vs. 80%, p <  0.001; 92% vs. 77%, p <  0.001). CNN assistance had no significant influence on their diagnostic performance and certainty. After self-training, the junior radiologists' specificity and accuracy improved and were comparable to that of the CNN. CONCLUSIONS: Diagnostic performance of the CNN for differentiating high-flow from low-flow VM was comparable to that of expert radiologists. CNN did not significantly improve the simulated daily practice of junior radiologists, self-training was more effective.

2.
Rofo ; 2024 Jan 18.
Artículo en Inglés, Alemán | MEDLINE | ID: mdl-38237631

RESUMEN

· Breast MRI is an essential part of breast imaging. · The recommendations for performing breast MRI have been updated. · A table provides a compact and quick overview. More detailed comments supplement the table.. · The "classic" breast MRI can be performed based on the recommendations. Tips for special clinical questions, such as implant rupture, mammary duct pathology or local lymph node status, are included.. ZITIERWEISE: · Wenkel E, Wunderlich P, Fallenberg E et al. Aktualisierung der Empfehlungen der AG Mammadiagnostik der Deutschen Röntgengesellschaft zur Durchführung der Mamma-MRT. Fortschr Röntgenstr 2024; DOI: 10.1055/a-2216-0782.

3.
Clin Hemorheol Microcirc ; 86(1-2): 121-131, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-37638426

RESUMEN

AIM: To evaluate the usefulness of handheld ultrasound in comparison with high-end ultrasound for lesion evaluation before and after sclerotherapy in pediatric patients with venous malformations (VMs). MATERIAL AND METHODS: 10 pediatric patients prior to and after sclerotherapy were scanned by an experienced examiner using handheld ultrasound (Vscan AirTM) and high-end ultrasound (LOGIQ E9/E10) as reference. Patients with associated venous thromboses and intralesional aneurysms had been excluded. Results were interpreted independently by two readers in consensus. RESULTS: 10 patients (4-17 years; 10.0±4.32 years; female n = 6, male n = 4) with 10 VMs (4 of the head and neck region, 4 of the upper and 2 of the lower extremities) were examined. 7 phleboliths were detected. The average rating score achieved by the high-end device never was less than 4, by Vscan AirTM never less than 3. An exception was the assessment of AV fistulas. In comparison with the evaluation of variables examined, we found a significant difference between the high-end scanner and the handheld device regarding the achieved image quality. CONCLUSION: Vscan AirTM ultrasound device allows new possibilities for procedure planning and post-procedural control of pediatric patients with VMs.


Asunto(s)
Malformaciones Vasculares , Humanos , Niño , Masculino , Femenino , Malformaciones Vasculares/diagnóstico por imagen , Malformaciones Vasculares/terapia , Ultrasonografía , Escleroterapia/métodos , Venas/diagnóstico por imagen , Cuello , Resultado del Tratamiento , Estudios Retrospectivos
4.
Angiogenesis ; 27(1): 91-103, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37733132

RESUMEN

Extracranial arteriovenous malformations (AVMs) are regarded as rare diseases and are prone to complications such as pain, bleeding, relentless growth, and high volume of shunted blood. Due to the high vascular pressure endothelial cells of AVMs are exposed to mechanical stress. To control symptoms and lesion growth pharmacological treatment strategies are urgently needed in addition to surgery and interventional radiology. AVM cells were isolated from three patients and exposed to cyclic mechanical stretching for 24 h. Thalidomide and bevacizumab, both VEGF inhibitors, were tested for their ability to prevent the formation of circular networks and proliferation of CD31+ endothelial AVM cells. Furthermore, the effect of thalidomide and bevacizumab on stretched endothelial AVM cells was evaluated. In response to mechanical stress, VEGF gene and protein expression increased in patient AVM endothelial cells. Thalidomide and bevacizumab reduced endothelial AVM cell proliferation. Bevacizumab inhibited circular network formation of endothelial AVM cells and lowered VEGF gene and protein expression, even though the cells were exposed to mechanical stress. With promising in vitro results, bevacizumab was used to treat three patients with unresectable AVMs or to prevent regrowth after incomplete resection. Bevacizumab controlled bleeding, pulsation, and pain over the follow up of eight months with no patient-reported side effects. Overall, mechanical stress increases VEGF expression in the microenvironment of AVM cells. The monoclonal VEGF antibody bevacizumab alleviates this effect, prevents circular network formation and proliferation of AVM endothelial cells in vitro. The clinical application of bevacizumab in AVM treatment demonstrates effective symptom control with no side effects.


Asunto(s)
Malformaciones Arteriovenosas , Células Endoteliales , Humanos , Células Endoteliales/metabolismo , Factor A de Crecimiento Endotelial Vascular/metabolismo , Bevacizumab/farmacología , Bevacizumab/uso terapéutico , Bevacizumab/metabolismo , Talidomida/metabolismo , Malformaciones Arteriovenosas/genética , Dolor/metabolismo
5.
Dent J (Basel) ; 11(8)2023 Aug 11.
Artículo en Inglés | MEDLINE | ID: mdl-37623289

RESUMEN

Aim of this study was to demonstrate the diagnostic ability to differentiate odontogenic keratocysts (OKCs) from ameloblastomas (AMs) based on computed tomography (CT) or cone beam computed tomography (CBCT) scans. Preoperative CT and CBCT scans from 2004 to 2019 of OKCs and AMs were analyzed in 51 participants. Lesions were three-dimensionally (3D) assessed and Hounsfield units (HU) as well as gray scale values (GSV) were quantified. Calculated HU spectra were compared within the same imaging modalities using unpaired t-tests and correlated with participants characteristics by calculating Pearsons correlation coefficients. Within the CT scans, AMs had highly significantly higher HU values compared to OKCs (43.52 HU and 19.79 HU, respectively; p < 0.0001). Analogous, within the CBCT scans, AMs had significantly higher GSV compared to OKCs (-413.76 HU and -564.76 HU, respectively; p = 0.0376). These findings were independent from participants' gender and age, anatomical site, and lesion size, indicating that the HU- and GSV-based difference reflects an individual configuration of the lesion. HU and GSV spectra calculated from CT and CBCT scans can be used to discriminate between OKCs and AMs. This diagnostic approach represents a faster and non-invasive option for preoperative diagnosis of such entities and has potential to facilitate therapeutic decision making.

6.
Tomography ; 9(4): 1515-1525, 2023 08 16.
Artículo en Inglés | MEDLINE | ID: mdl-37624114

RESUMEN

Orbital floor fractures (OFFs) are common injuries of the midface and may result in long-term complications. The aim of this study was to compare two restoration materials, PDS foils and titanium meshes, with regards to (1) clinical outcome and (2) reduction in orbital volume. The monocentric discovery cohort was analyzed retrospectively and included 476 patients with OFFs treated between 2010 and 2020. A subcohort of 104 patients (study cohort) with isolated OFFs and available high-resolution imaging material was used for volume measurements. Postoperative complications were not significantly different between patients treated with different restoration materials. Prevalence of revision surgery was significantly higher in patients treated with thick PDS foils (25 mm). OFFs treated with PDS foils and titanium meshes showed a significant reduction in orbital volume (p = 0.0422 and p = 0.0056, respectively), however, this volume decrease was significantly less pronounced in patients treated with PDS foils alone (p = 0.0134). Restoration using PDS foil in an isolated OFF reduces the orbital volume to a lesser extent than titanium mesh. Class III patients according to the classification of Jaquiéry with a missing bony ledge medial to the infraorbital fissure particularly benefit from restoration with PDS foils due to a lower reduction in the orbital volume. Regarding short- and long-term postoperative complications, a PDS foil thickness of 0.15 mm appears equivalent to titanium mesh in the treatment of OFFs.


Asunto(s)
Complicaciones Posoperatorias , Titanio , Humanos , Estudios Retrospectivos , Complicaciones Posoperatorias/diagnóstico por imagen
7.
Cancers (Basel) ; 15(15)2023 Jul 29.
Artículo en Inglés | MEDLINE | ID: mdl-37568670

RESUMEN

BACKGROUND: The intraoperative detection of solitary pulmonary nodules (SPNs) continues to be a major challenge, especially in minimally invasive video-assisted thoracic surgery (VATS). The location, size, and intraoperative frozen section result of SPNs are decisive regarding the extent of lung resection. This feasibility study investigates the technical applicability of intraoperative contrast-enhanced ultrasonography (Io-CEUS) in minimally invasive thoracic surgery. METHODS: In this prospective, monocentric clinical feasibility study, n = 30 patients who underwent Io-CEUS during elective minimally invasive lung resection for SPNs between October 2021 and February 2023. The primary endpoint was the technical feasibility of Io-CEUS during VATS. Secondary endpoints were defined as the detection and characterization of SPNs. RESULTS: In all patients (female, n = 13; mean age, 63 ± 8.6 years) Io-CEUS could be performed without problems during VATS. All SPNs were detected by Io-CEUS (100%). SPNs had a mean size of 2.2 cm (0.5-4.5 cm) and a mean distance to the lung surface of 2.0 cm (0-6.4 cm). B-mode, colour-coded Doppler sonography, and contrast-enhanced ultrasound were used to characterize all tumours intraoperatively. Significant differences were found, especially in vascularization as well as in contrast agent behaviour, depending on the tumour entity. After successful lung resection, a pathologic examination confirmed the presence of lung carcinomas (n = 17), lung metastases (n = 10), and benign lung tumours (n = 3). CONCLUSIONS: The technical feasibility of Io-CEUS was confirmed in VATS before resection regarding the detection of suspicious SPNs. In particular, the use of Doppler sonography and contrast agent kinetics revealed intraoperative specific aspects depending on the tumour entity. Further studies on Io-CEUS and the application of an endoscopic probe for VATS will follow.

8.
Rofo ; 195(8): 699-706, 2023 08.
Artículo en Inglés, Alemán | MEDLINE | ID: mdl-37348527

RESUMEN

PURPOSE: Breast imaging represents an integral part of radiology and is subject to strict quality controls. Regarding this, precise diagnostics including multimodal assessment by mammography, sonography, and MRI, including image-guided biopsy and localization procedures, is often decisive and must be performed by experts with profound knowledge and skills in all of these procedures.However, due to numerous restructurings, breast imaging has been shifted more and more towards large, specialized centers, resulting in less patient exposition and training opportunities for radiologists in smaller sites. The following whitepaper summarizes the current circumstances and discusses opinions of the participating societies. MATERIALS: Under the leadership of the German Roentgen Society (DRG) and with the participation of the DRG's AG Mammadiagnostik, the CAFRAD (Chefarztforum Radiologie), the KLR (Konferenz der Lehrstuhlinhaber für Radiologie e. V.), the DRG's Forum Junge Radiologie (FJR) and the Berufsverband der Deutschen Radiologen e. V. (BDR), possible solutions were discussed and consented for a structured training in breast radiology in the future. RESULTS: In addition to the teaching provided at the primary workplace, qualified training should be ensured through flexible, multi-institutional, interdisciplinary, and cross-sectoral collaboration. Furthermore, the integration of online case collections and close cooperation with certified breast cancer centers and mammography screening units is recommended. It is indispensible that online courses and case collections adhere to the standards of the national societies and include a maximum of one third of the required cases. CONCLUSION: In order to provide training in breast radiology at a high professional level, a paradigm shift with closer cooperation of all participants is necessary. This includes close collaboration of the breast imaging societies with the federal medical associations to establish new teaching concepts like e-learning in the training schedule of radiologists. KEY POINTS: · Breast diagnostics is an integral part of radiology training.. · Due to recent restructurings, smaller training centers have difficulties in meeting the case numbers demanded by the Specialist Training Regulations (WBO). Improved integration of the new structures and their adaptation to the needs of education are necessary to guarantee standardized high-quality training of young radiologists.. · The integration of certified case collections enables quality-assured training, even across regions in online-based formats. In accordance with the "blended learning principle", up to one-third of the required number of patient studies can be substituted with cases from a certified case collection.. · Legally secured short- and medium-term internships may complement training in radiology.. CITATION FORMAT: · Sauer ST, Bley TA, Wenkel E et al. Whitepaper: Training in Diagnostic and Interventional Breast Radiology. Fortschr Röntgenstr 2023; 195: 699 - 706.


Asunto(s)
Curriculum , Radiología Intervencionista , Humanos , Aprendizaje , Mamografía , Ultrasonografía
9.
Tomography ; 9(2): 579-588, 2023 03 05.
Artículo en Inglés | MEDLINE | ID: mdl-36961006

RESUMEN

Orbital floor fractures represent a common fracture type of the midface and are standardly diagnosed clinically as well as radiologically using linear measurement methods. The aim of this study was to evaluate the accuracy of diagnostic measurements of isolated orbital floor fractures based on two-dimensional (2D) and three-dimensional (3D) measurement techniques. A cohort of 177 patients was retrospectively and multi-centrically evaluated after surgical treatment of an orbital floor fracture between 2010 and 2020. In addition to 2D and 3D measurements of the fracture area, further fracture-related parameters were investigated. Calculated fracture areas using the 2D measurement technique revealed an average area of 287.59 mm2, whereas the 3D measurement showed fracture areas with a significantly larger average value of 374.16 mm2 (p < 0.001). On average, the 3D measurements were 1.53-fold larger compared to the 2D measurements. This was observed in 145 patients, whereas only 32 patients showed smaller values in the 3D-based approach. However, the process duration of the 3D measurement took approximately twice as long as the 2D-based procedure. Nonetheless, 3D-based measurement of orbital floor defects provides a more accurate estimation of the fracture area than the 2D-based procedure and can be helpful in determining the indication and planning the surgical procedure.


Asunto(s)
Fracturas Orbitales , Humanos , Estudios Retrospectivos , Fracturas Orbitales/diagnóstico por imagen , Fracturas Orbitales/cirugía , Órbita/cirugía , Tomografía Computarizada por Rayos X/métodos
10.
Tomography ; 9(2): 681-692, 2023 03 16.
Artículo en Inglés | MEDLINE | ID: mdl-36961013

RESUMEN

BACKGROUND: Modern ultrasound (US) shear-wave dispersion (SWD) and attenuation imaging (ATI) can be used to quantify changes in the viscosity and signal attenuation of the liver parenchyma, which are altered in hepatic steatosis. We aimed to evaluate modern shear-wave elastography (SWE), SWD and ATI for the assessment of hepatic steatosis. METHODS: We retrospectively analyzed the US data of 15 patients who underwent liver USs and MRIs for the evaluation of parenchymal disease/liver lesions. The USs were performed using a multifrequency convex probe (1-8 MHz). The quantitative US measurements for the SWE (m/s/kPa), the SWD (kPa-m/s/kHz) and the ATI (dB/cm/MHz) were acquired after the mean value of five regions of interest (ROIs) was calculated. The liver MRI (3T) quantification of hepatic steatosis was performed by acquiring proton density fat fraction (PDFF) mapping sequences and placing five ROIs in artifact-free areas of the PDFF scan, measuring the fat-signal fraction. We correlated the SWE, SWD and ATI measurements to the PDFF results. RESULTS: Three patients showed mild steatosis, one showed moderate steatosis and eleven showed no steatosis in the PDFF sequences. The calculated SWE cut-off (2.5 m/s, 20.4 kPa) value identified 3/4 of patients correctly (AUC = 0.73, p > 0.05). The SWD cut-off of 18.5 m/s/kHz, which had a significant correlation (r = 0.55, p = 0.034) with the PDFF results (AUC = 0.73), identified four patients correctly (p < 0.001). The ideal ATI (AUC = 0.53 (p < 0.05)) cut-off was 0.59 dB/cm/MHz, which showed a significantly good correlation with the PDFF results (p = 0.024). CONCLUSION: Hepatic steatosis can be accurately detected using all the US-elastography techniques applied in this study, although the SWD and the SWE showed to be more sensitive than the PDFF.


Asunto(s)
Diagnóstico por Imagen de Elasticidad , Humanos , Diagnóstico por Imagen de Elasticidad/métodos , Estudios Retrospectivos , Hígado/diagnóstico por imagen , Ultrasonografía/métodos , Imagen por Resonancia Magnética/métodos
11.
Plast Reconstr Surg ; 152(4): 866-870, 2023 10 01.
Artículo en Inglés | MEDLINE | ID: mdl-36780356

RESUMEN

BACKGROUND: In the setting of facial palsy, synkinesis of the depressor anguli oris (DAO) muscle is a common pathology, impairing dynamic and resting facial symmetry.In this prospective study, the authors used high-resolution ultrasound (HRUS) to evaluate the morphologic features of DAO and to quantify bilateral differences in DAO cross-sectional diameter (CSD) in individuals with unilateral synkinesis. METHODS: From June of 2020 to May of 2021, 30 patients (19 women, 11 men) with clinically diagnosed unilateral synkinesis underwent evaluation with HRUS. DAO CSD was measured bilaterally, 1 cm inferior to the modiolus, in both the resting and smiling positions. RESULTS: The Sunnybrook Facial Grading System Synkinesis Score was 6.20 ± 2.48 (range, 0 to 10). DAO CSD at rest measured 2.41 ± 0.67 mm (range, 1.40 to 4.00 mm) on the control side and 2.66 ± 0.98 mm (range, 1.60 to 5.10 mm) on the affected side. On the control side, DAO CSD was reduced by -0.19 ± 0.43 mm (range, -1.10 to 1.12 mm) during smiling. In contrast, the synkinetic DAO CSD increased by 0.64 ± 0.38 mm (range, 0.00 to 1.59 mm) ( P < 0.001) with animation. The pattern of increased CSD in synkinetic DAO muscles and decreased or unchanged CSD on the control side during smiling was identified in 70% of patients. CONCLUSIONS: HRUS demonstrates increased CSD in synkinetic DAO muscles during active smiling. The opposite is true for DAO muscles on the control side, which exhibit decreased CSD with animation. HRUS can be performed preoperatively to objectify DAO dysfunction and guide targeted therapy. CLINICAL QUESTION/LEVEL OF EVIDENCE: Diagnostic, IV.


Asunto(s)
Parálisis Facial , Sincinesia , Masculino , Humanos , Femenino , Estudios Prospectivos , Músculos Faciales/diagnóstico por imagen , Parálisis Facial/cirugía , Sonrisa/fisiología
12.
Diagnostics (Basel) ; 12(8)2022 Jul 30.
Artículo en Inglés | MEDLINE | ID: mdl-36010193

RESUMEN

BACKGROUND: We aimed to evaluate multiparametric ultrasound, to achieve a better understanding of the baseline characteristics of suspected cervical lymph node metastases in head and neck cancer before induction chemotherapy or chemoradiation. METHODS: From February 2020 to April 2021, our complete ultrasound examination protocol was carried out on clinically evident malignant lymph nodes of histologically proven HNSCC in the pre-therapeutic setting. RESULTS: A total of 13 patients were eligible for analysis. Using elastography, irregular clear hardening in areas in the center of the lymph node could be detected in all cases. Elastographic Q-analysis showed a significantly softer cortex compared to the center and surrounding tissue. The time-intensity curve analysis showed high values for the area under the curve and a short time-to-peak (fast wash-in) in all cases compared to the surrounding tissue. A parametric evaluation of contrast enhanced the ultrasound in the early arterial phase and showed an irregular enhancement from the margin in almost all investigated lymph nodes. These results show that the implementation of comprehensive, multiparametric ultrasound is suitable for classifying suspected lymph node metastasis more precisely than conventional ultrasound alone in the pre-therapeutic setting of HNSCC. Thus, these parameters may be used for improvements in the re-staging after chemoradiation or neoadjuvant therapy monitoring, respectively.

13.
Diagnostics (Basel) ; 12(7)2022 Jul 07.
Artículo en Inglés | MEDLINE | ID: mdl-35885554

RESUMEN

BACKGROUND: Synkinesis of the facial musculature is a detrimental sequalae in post-paralytic facial palsy (PPFP) patients. Detailed knowledge on the technical requirements and device properties in a high-resolution ultrasound (HRUS) examination is mandatory for a reliable facial muscle assessment in PPFP patients. We therefore aimed to outline the key steps in a HRUS examination and extract an optimized workflow schema. METHODS: From December 2020 to April 2021, 20 patients with unilateral synkinesis underwent HRUS. All HRUS examinations were performed by the first author using US devices with linear multifrequency transducers of 4-18 MHz, including a LOGIQ E9 and a LOGIQ S7 XDclear (GE Healthcare; Milwaukee, WI, USA), as well as Philips Affinity 50G (Philips Health Systems; Eindhoven, the Netherlands). RESULTS: Higher-frequency and multifrequency linear probes ≥15 MHz provided superior imaging qualities. The selection of the preset program Small Parts, Breast or Thyroid was linked with a more detailed contrast of the imaging morphology of facial tissue layers. Frequency (Frq) = 15 MHz, Gain (Gn) = 25-35 db, Depth (D) = 1-1.5 cm, and Focus (F) = 0.5 cm enhanced the image quality and assessability. CONCLUSIONS: An optimized HRUS examination protocol for quantitative and qualitative facial muscle assessments was proposed.

15.
J Clin Med ; 11(9)2022 Apr 29.
Artículo en Inglés | MEDLINE | ID: mdl-35566629

RESUMEN

Introduction: The fast and accurate diagnosis of rib fractures in polytrauma patients is important to reduce the mortality rate and relieve long-term pain and complications. Aim: To evaluate the diagnostic accuracy and potential time savings using automatic rib segmentation and a curved, unfolded view for the detection of rib fractures in trauma patients. Methods: The multidetector computed tomography raw data of 101 consecutive polytrauma patients (72 men; mean age 45 years, age range 17 to 84 years) admitted to a university hospital were retrospectively post-processed to generate a curved, unfolded view of the rib cage. No manual corrections were performed. Patients with reconstruction errors and movement artifacts were excluded from further analysis. All fractures were identified and classified by the study coordinator using the original data set. Two readers (reader 1 and reader 2) evaluated the original axial sections and the unfolded view, separately. The fracture locations, fracture type, and reading times were recorded. Sensitivity and specificity were calculated on a per-rib basis using a ratio estimator. Cohen's Kappa was calculated as an index of inter-rater agreement. Results: 26 of 101 patients (25.7%) were excluded from further analysis owing to breathing artifacts (6.9%) or incorrect centerline computation in the unfolded view (18.8%). In total, 107 (5.9%) of 1800 ribs were fractured in 25 (33%) of 75 patients. The unfolded view had a sensitivity/specificity of 81%/100% (reader 1) and 71%/100% (reader 2) compared to 94%/100% (reader 1; p = 0.002/p = 0.754) and 63%/99% (reader 2; p < 0.001/p = 0.002). The sensitivity (reader 1; reader 2) was poor for buckled fractures (31%; 38%), moderate for undislocated fractures (78%; 62%), and good for dislocated fractures (94%; 90%). The assessment of the unfolded view was performed significantly faster than that of the original layers (19.5 ± 9.4 s vs. 68.6 ± 32.4 s by reader 1 (p < 0.001); 24.1 ± 9.5 s vs. 40.2 ± 12.7 s by reader 2 (p < 0.001)). Both readers demonstrated a very high interobserver agreement for the unfolded view (κ = 0.839) but only a moderate agreement for the original view (κ = 0.529). Conclusion: Apart from a relatively high number of incorrect centerline reconstructions, the unfolded view of the rib cage allows a faster diagnosis of dislocated rib fractures.

16.
Rofo ; 194(3): 272-280, 2022 03.
Artículo en Inglés, Alemán | MEDLINE | ID: mdl-34794186

RESUMEN

PURPOSE: Comparison of puncture deviation and puncture duration between computed tomography (CT)- and C-arm CT (CACT)-guided puncture performed by residents in training (RiT). METHODS: In a cohort of 25 RiTs enrolled in a research training program either CT- or CACT-guided puncture was performed on a phantom. Prior to the experiments, the RiT's level of training, experience playing a musical instrument, video games, and ball sports, and self-assessed manual skills and spatial skills were recorded. Each RiT performed two punctures. The first puncture was performed with a transaxial or single angulated needle path and the second with a single or double angulated needle path. Puncture deviation and puncture duration were compared between the procedures and were correlated with the self-assessments. RESULTS: RiTs in both the CT guidance and CACT guidance groups did not differ with respect to radiologic experience (p = 1), angiographic experience (p = 0.415), and number of ultrasound-guided puncture procedures (p = 0.483), CT-guided puncture procedures (p = 0.934), and CACT-guided puncture procedures (p = 0.466). The puncture duration was significantly longer with CT guidance (without navigation tool) than with CACT guidance with navigation software (p < 0.001). There was no significant difference in the puncture duration between the first and second puncture using CT guidance (p = 0.719). However, in the case of CACT, the second puncture was significantly faster (p = 0.006). Puncture deviations were not different between CT-guided and CACT-guided puncture (p = 0.337) and between the first and second puncture of CT-guided and CACT-guided puncture (CT: p = 0.130; CACT: p = 0.391). The self-assessment of manual skills did not correlate with puncture deviation (p = 0.059) and puncture duration (p = 0.158). The self-assessed spatial skills correlated positively with puncture deviation (p = 0.011) but not with puncture duration (p = 0.541). CONCLUSION: The RiTs achieved a puncture deviation that was clinically adequate with respect to their level of training and did not differ between CT-guided and CACT-guided puncture. The puncture duration was shorter when using CACT. CACT guidance with navigation software support has a potentially steeper learning curve. Spatial skills might accelerate the learning of image-guided puncture. KEY POINTS: · The CT-guided and CACT-guided puncture experience of the RiTs selected as part of the program "Researchers for the Future" of the German Roentgen Society was adequate with respect to the level of training.. · Despite the lower collective experience of the RiTs with CACT-guided puncture with navigation software assistance, the learning curve regarding CACT-guided puncture may be faster compared to the CT-guided puncture technique.. · If the needle path is complex, CACT guidance with navigation software assistance might have an advantage over CT guidance.. CITATION FORMAT: · Meine TC, Hinrichs JB, Werncke T et al. Phantom study for comparison between computed tomography- and C-Arm computed tomography-guided puncture applied by residents in radiology. Fortschr Röntgenstr 2022; 194: 272 - 280.


Asunto(s)
Radiología , Tomografía Computarizada por Rayos X , Humanos , Fantasmas de Imagen , Punciones/métodos , Programas Informáticos , Tomografía Computarizada por Rayos X/métodos
17.
J Clin Med ; 10(11)2021 May 30.
Artículo en Inglés | MEDLINE | ID: mdl-34070779

RESUMEN

The superficial circumflex iliac artery perforator (SCIP) flap is a well-documented, thin, free tissue flap with a minimal donor site morbidity, and has the potential to become the new method for resurfacing moderate-size skin defects. The aim of this study is to describe an easy, reliable, systematic, and standardized approach for preoperative SCIP flap design and perforator characterization, using color-coded duplex sonography (CCDS). A list of customized settings and a straightforward algorithm are presented, which are easily applied by an operator with minimal experience. Specific settings for SCIP flap perforator evaluation were investigated and tested on 12 patients. Deep and superficial superficial circumflex iliac artery (SCIA) branches, along with their corresponding perforators and cutaneous veins, were marked individually with a permanent marker and the anatomy was verified intraoperatively. From this, a simplified procedure for preoperative flap design of the SCIP flap was developed. Branches could be localized and evaluated in all patients. A preoperative structured procedure for ultrasonically guided flap design of the SCIP flap is described. A 100% correlation between the number and emergence points of the branches detected by preoperative CCDS mapping and the intraoperative anatomy was found.

18.
J Ultrasound Med ; 40(8): 1613-1625, 2021 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-33124700

RESUMEN

OBJECTIVES: To evaluate intraoperative contrast-enhanced ultrasound (IoCEUS) and intraoperative shear wave elastography (IoSWE) for characterization of focal pancreatic lesions (FPLs) in correlation with postoperative histologic results. Thereby, the impact of intraoperative ultrasound (US) on pancreas surgery was evaluated. METHODS: Intraoperative CEUS and SWE data from 54 patients, who underwent pancreas surgery between 2017 and 2019, were analyzed retrospectively. Ultrasound examinations were performed with multifrequency linear/T-shaped transducers (3-9 MHz) on a high-end US device (LOGIQ E9; GE Healthcare, Chicago, IL). To analyze FPL stiffness by SWE, regions of interest were placed to measure the shear wave speed (meters per second) and stiffness (kilopascals). After intravenous bolus injections of 2.4 to 10 mL of sulfur hexafluoride microbubbles, a dynamic analysis of FPL microvascularization from arterial to late phases was performed using IoCEUS considering hypoenhancement/irregular vascularization of macrocystic/small solid FPL malignancy criteria. Ultrasound findings were correlated with postoperative histologic results. The impact of intraoperative US on surgery was documented in each case. RESULTS: Of 54 FPLs, IoCEUS could correctly characterize 39 of 39 malignant and 6 of 15 benign FPLs; IoSWE 29 of 39 as malignant and 7 of 15 as benign. Intraoperative CEUS's sensitivity was 100%; specificity, 40%; accuracy, 83.3%; positive predictive value, 81.3%; and negative predictive value, 100% (P < .05). Applying cutoff values of 3 m/s and 28.7 kPa, SWE's sensitivity was 74.4%; specificity, 46.7%; accuracy, 66.7%; positive predictive value; 78.4%; and negative predictive value, 41.2% for cancer detection (P < .05). The combined use of both techniques showed an accuracy rate of 76%, sensitivity of 74.4%, and specificity of 33.3%. In 29.6%, US results had an immediate impact on surgery. CONCLUSIONS: Intraoperative SWE and CEUS are highly valuable techniques for intraoperative characterization of FPLs. Although IoCEUS proved to be superior to IoSWE, the combined use can be helpful in particular cases.


Asunto(s)
Diagnóstico por Imagen de Elasticidad , Neoplasias Pancreáticas , Humanos , Neoplasias Pancreáticas/diagnóstico por imagen , Neoplasias Pancreáticas/cirugía , Estudios Retrospectivos , Sensibilidad y Especificidad , Hexafluoruro de Azufre , Ultrasonografía
20.
Clin Hemorheol Microcirc ; 76(4): 559-572, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32924994

RESUMEN

OBJECTIVE: To investigate the diagnostic accuracy of high-resolution ultrasound (HRU) for the detection of hepatic metastases of breast cancer in a humanized tumour mouse (HTM) using clinical standard technology. In addition, the efficiency of standard contrast-enhanced ultrasound (CEUS) [microbubbles of sulphur hexafluoride] and CEUS using a novel VEGFR2-targeted contrast agent [BR55®] was examined. METHODS: A total of 14 HTM were sonographically examined twice. In addition to a human immune system, the animals developed hepatic tumour lesions after intrahepatic injection of BT-474 breast cancer cells. Digital cine loops from the arterial phase (15-35 sec), the portal venous phase (35-90 sec) and the late phase (3-15 min) of the entire liver were analysed. Data were correlated to histopathology. RESULTS: After 9 months, half of the mice (7/14) revealed the development of hepatic breast cancer metastases. The detection limit was 1 mm tumour diameter. In particular, the use of targeted contrast media reduced the needed tumour diameter and helped to precisely classify tumour tissue. In 93% (13/14), the findings of ultrasound could be approved by histological examination by the pathologist. CONCLUSIONS: This study in HTM demonstrated the high feasibility of tumour specific contrast media and standard HRU contrast agents to detect early liver metastases.


Asunto(s)
Neoplasias de la Mama/complicaciones , Medios de Contraste/uso terapéutico , Neoplasias Hepáticas/secundario , Ultrasonografía/métodos , Animales , Neoplasias de la Mama/patología , Femenino , Humanos , Neoplasias Hepáticas/patología , Ratones , Persona de Mediana Edad , Metástasis de la Neoplasia